Phihong’s POE480U multiport midspan is a 60W Ultra Power midspan injector, functionally compliant to the IEEE802.3at standards but with 2-pair injection and 12.5 KΩ handshake detection. This multiport midspan injector can fully provide 60W per port over Cat5e/Cat6 cables into 10/100/1000 BaseT systems, eliminating the need for power management and prioritization. The midspans have an optional NIC interface. Each product is provided with a graphics user interface (GUI) for diagnostics or remote control.
Applications
| IP Cameras; Wireless Network Access Points | Computer Workstations; Security Systems |
Features
| Proprietary Detection, Disconnect & overload Protection | Full Protection OTP, OCP, OVP |
| Full Power of 60W per port | No Power Management required |
| Gigabit Compatible; low cost solution | 14 Rack mountable; 48V RPS Input (optional) |
Output
| POE480U-8UP | POE480U-16UP | |
| Output | 60W per port | 60W per port |
| Load/ port | 60W | 60W |
| Regulation | 100mV max. | |
| Option: (X) | = N for SNMP Management | |
Safety
| Isolation Test | Primary to Secondary | 4242VDC for 1min. 10mA |
| Primary to F.G. | 2121VDC for 1 minute | |
| Output to F.G. | 2121VDC |
Input
| AC Input Voltage Range / AC Input Frequency | 90 to 264 VAC / 47-63 Hz |
| Leakage Current | 3.5 mA max @ 254 VAC 60 Hz |
| AC Inrush Current | 30A (RMS) max for 115VAC |
| AC Input Current | 7.5A for 90VAC / 3A for 240VAC |
General
| Efficiency | 75% (typical) at max. load and 120VAC 60Hz |
| Hold-up Time | 16mS min. 120VAC/ 60Hz and max. load |
| Transient O/P Voltage Protection | 60V max. at switch on and off at any AC line Phase |
| Turn-On Delay Time | 10sec max. at max. load, and 120VAC 60Hz, 25Hz |
| IEEE 802.3af Interoperability | UNH Interoperability report available on request |
| If 25kOhm is detected the unit operates in “IEEE802.3at mode” 33.6W 2pair powering. 12.5kOhm detection resistance required for full power. | |
EMC
| Conducted & radiated Emission | FCC Part 15 Class B with FTP cabling | ||||||||||||||
| EN55022 Class B (Class A with UTP cabling) | |||||||||||||||
| Immunity EN50082-1 |
|
Environmental
| Temperature |
| Operation 0 to +40°C Non-operation -25 to +65°C |
| Humidity |
| Operation 5 to 90% |