Phihong’s multi output gigabit PoE midspan POE370U-480 series are fully complaint to IEEE802.3af standards. Models with 8, 16 or 24 ports are available. Each product can fully provide 15.4W per port over Cat5/Cat5e/Cat6 cables for 10/100/1000 BaseT systems, eliminating the need for power management and prioritization. The midspans have Cisco legacy detection without the need of external dongles, as well as an optional NIC interface.
Each product is provided with a Phihong graphics user interface (GUI) for diagnostics or remote control via the USB port on the standard model.
Applications
| IP Telephones; Wireless Network Access Points | Lighting Systems with Single UPS; Security Systems |
Features
| Fully Compliant with IEEE802.3af | 10/100/1000 base T compatible; NIC Interface (optional) |
| Full Power of 370-15,4W per port; Cisco Legacy detection | Full Protection OTP, OCP, OVP; 48V RPS Input (optional) |
Output
| POE370U-480-8-(X) | POE370U-480-16-(X) | POE370U-480-24-(X) | |
| DC Output Voltage (No. of Ports) | 15.4W per port (8) | 15.4W per port (16) | 15.4W per port(24) |
| Optional code (X) | blank for standard product with no option; “N” includes SNMP, Simple Network Management Protocol; “R” RPS DC input; “RN” for RPS input and SNMP | ||
Safety
| Isolation Test | Primary to Secondary | 4242VDC for 1min. 10mA |
| Primary to F.G. | 2121VDC for 1 minute | |
| Output to F.G. | 2121VDC for 1 minute | |
| Insulation Resistance | Primary to secondary | >10M OHM 500 VDC |
| Primary to F.G. | >10M OHM 500 VDC |
Input
| AC Input Voltage Range | 90 to 264 VAC |
| Leakage Current | 3.5 mA max @ 254 VAC 60 Hz |
| AC Input Frequency | 47-63 Hz |
| AC Inrush Current | 30A(RMS) max. for 115VAC/ 60A(RMS) max. for 230VAC |
| AC Input Current | 5.5A for 90VAC / 2.75A for 240VAC |
General
| Efficiency | 75% (typical) at max. load and 120VAC 60Hz |
| Hold-up Time | 16mS min. 120VAC and max. load |
| Transient O/P Voltage Protection | 60V max. at switch on and off at any AC line Phase |
| Turn-On Delay Time | 3 sec max. at max. load, and 120VAC 60Hz, 25Hz |
| USB Diagnostics Port | USB “B” port for diagnostics & manual port control Windows GUI |
| Regulation | Functional requirements of IEEE802.3af |
EMC
| Conducted & radiated Emission | EN55022 Class A, FCC Class A with UTP Cabling | ||||||||||||||
| EN55022 Class B, FCC Class B with FTP Cabling | |||||||||||||||
| Immunity EN50082-1 |
|
Environmental
| Temperature |
| Operation 0 to +40°C Non-operation -25 to +65°C |
| Humidity |
| Operation 5 to 90% |