Phihong’s POE60S-4AF cans double the effective PoE Range of their devices to 200 meters. By using your standard RJ45 connecting Ethernet cables the POE60S-1AF takes its power from an IEEE802.3at device (33.6W) or higher (Ultra or Mega PoE). The output is converted to be IEEE802.3af compatible at 15.4W. The device can also act as a switch by itself. It has an optional AC power adapter which can power all four ports at 15.4W per port. Should the input power for the POE60S be 33.4W or lower the output power will decrease linearly.
Applications
| IP Cameras | Wireless Access Points |
| Access Controls | IP Telephones |
Features
| 4 Ports 15.4W per port | Full power Every Port |
| 10/100 Base-T Data Rates | Extends Ethernet to 200meters |
| Powered by Ultra POE or Optional DC power adapter | Boost Circuit to Compensate for Wire Drops |
Output
| Output Power | 15.4W per port on 4 ports Total power-62W |
| Detects a 25kOHM Signature Resistance | |
Safety
| Isolation | Input and output are isolated from chassis ground | |
| Isolation Test | Input to F.G. | 2121 VDC for 1 minute |
| Output to F.G. | 2121 VDC for 1 minute | |
| Insulation Resistance | Input and Output to field ground: >10 OHM 500VDC | |
Input
| The PoE Extender can receive power from the network switch or midspan. An optional DC power adapter is also available. | |
| DC Input Voltage Range | 36-57VDC |
| DC Input Current | 3.0mA at 36VDC at maximum load 2.0mA at 57VDC at maximum load |
General
| Efficiency | 84% (typical) at full load and 48VDC |
| PoE Standard Compliance | Input: 12.5K Internal Signature Resistance |
| Output: Detects a 25K Signature Resistance | |
| Ripple and Noise | 100mV maximum |
| Cable | Designed to operate up to100m per IEEE802.3,Cat5/Cat6 |
| Over Voltage/Current, Short Circuit Protection | Outputs equipped with short circuit protection and overload protection as per 802.3at specification |
| Input and Output Data Connector | RJ45 |
| Optional DC Input Connector | Center Positive Barrel 9mm x 2.5mm ID x 5.5mm OD |
EMC
| Conducted & radiated Emission | EN55022 Class B | FCC Part 15, Class B |
| Immunity | ESD | EN61000-4-2. Level 3 |
| RS | EN61000-4-3. Level 2 | |
| CS | EN61000-4-6. Level 2 | |
| Note: RS and CS tested with POE75U-560(G) | ||
Environmental
| Temperature |
| Operation 0 to +55°C Non-operation -20 to +71°C |
| Humidity |
| Operation 5 to 90% |